Medical Technologies

Amplicon Detection Reagent Kit for Metallo-ß-Lactamase NDM, Serine Carbapenemase Groups OXA-48-like, and KPC Genes using Isothermal Amplification "AmplicTest® CP NDM/OXA-48/KPC LAMP"

Amplicon Detection Reagent Kit for Metallo-ß-Lactamase NDM, Serine Carbapenemase Groups OXA-48-like, and KPC Genes using Isothermal Amplification "AmplicTest® CP NDM/OXA-48/KPC LAMP"

Configuration Options:

  1. Option I:

    Form 1 includes "RIBO-prep TS" kits variant 100 and "LAMP kit" variant FRT-96 F:

    • "RIBO-prep TS" variant 100 - a set of reagents for preliminary processing and extraction of total RNA/DNA from biological material, including:
      • Lysis solution - 30 mL x 1
      • Precipitation solution - 20 mL x 2
      • Wash solution 3 - 25 mL x 2
      • Wash solution 4 - 20 mL x 1
      • RNA buffer - 1.2 mL x 8
      • TS-Allegro - 12 mL x 1
    • "LAMP kit" variant FRT-96 F - a set of reagents for isothermal amplification of gene fragments of Metallo-ß-Lactamase NDM, Serine Carbapenemase Groups OXA-48-like, and KPC with real-time fluorescence detection, including:
      • LAMP mix-FL NDM - 0.3 mL x 2
      • LAMP mix-FL KPC/OXA-48 - 0.3 mL x 2
      • LAMP buffer-AMK - 1.2 mL x 2
      • Bst polymerase AMR - 0.12 mL x 1
      • K - 0.2 mL x 1
  2. Option II:

    Form 2 includes "Magno-Sorb-Combo TS" kits variant 100 and "LAMP kit" variant FRT-96 F:

    • "Magno-Sorb-Combo TS" variant 100 - a set of reagents for preliminary processing and extraction of total RNA/DNA from biological material, including:
      • Combo lysis buffer - 50 mL x 1
      • Buffer GT - 1 mL x 1
      • Magnetic sorbent - 1 mL x 2
      • Combo wash solution 1 - 70 mL x 1
      • Combo wash solution 2 - 50 mL x 1
      • RNA buffer - 1.2 mL x 8
      • TS-Allegro - 12 mL x 1
    • "LAMP kit" variant FRT-96 F - a set of reagents for isothermal amplification of gene fragments of Metallo-ß-Lactamase NDM, Serine Carbapenemase Groups OXA-48-like, and KPC with real-time fluorescence detection, including:
      • LAMP mix-FL NDM - 0.3 mL x 2
      • LAMP mix-FL KPC/OXA-48 - 0.3 mL x 2
      • LAMP buffer-AMR - 1.2 mL x 2
      • Bst polymerase AMR - 0.12 mL x 1
      • K - 0.2 mL x 1

To purchase the Amplicon Detection Reagent Kit for Metallo-ß-Lactamase NDM, Serine Carbapenemase Groups OXA-48-like, and KPC Genes using Isothermal Amplification "AmplicTest® CP NDM/OXA-48/KPC LAMP," please fill out the order form on our website or email us at Адрес электронной почты защищен от спам-ботов. Для просмотра адреса в вашем браузере должен быть включен Javascript..

Copyright MAXXmarketing GmbH
JoomShopping Download & Support